EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE1END TO END (BARRIER)OPTICAL BEAM LINEARSMOKE DETECTORRK100B - RK200BUSER GUIDETECHNICAL INSTRUC
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE106 - OPERATION6.1 - the RK100/200B detector is equipped with 2 circuits of detection of the smo
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE117 - OPTICAL ALIGNMENT7.1 - proceed with the optical alignment of Transmitter TX and Receiver R
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE128 - SETUP OF THE OBSCURATION CIRCUITElectric signal setup must be performed according to the
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE138.12 - search for the maximum output signal optimizing the optical alignment of the Transmitte
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE14• if the signal overcomes 4 V, the blue Led flashes faster and faster as the frequency signal
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE159 - SETUP OF THE TURBULENCE CIRCUIT9.1 - The RK100/200B detector is equipped with a special ad
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE1610 - DETECTOR’S ACTIVATION10.1 - on the RX, put the jumper of Initial Setup, JP1, in OFF ALI (
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE1712 - OPERATIONAL TEST12.1 - verification of the circuit sensible to obscurationThe verificatio
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE1813 -FAULT OUTPUT13.1 - the fault relay contact is available on the terminal block of the RX.Th
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE1916 - MAINTENANCE16.1 - the instrument requires an easy and periodic maintenance. It can be pro
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE2CHAPTER INDEX1 - Qualified Personell2 -Normative references3 - Installation4 - Cable Connection
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE20TECHNICAL DATA• Models: RK100B, RK200B• Type: Barrier Optical Beam Smoke Detector• Manufacture
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE21TX RXfig.1AAAAfig.2
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE22rivelatoreLAL 02lampadafig.3disco biancowhite discdiodo fotoemittentephotoemitting diodeforoho
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE2301020304050600102030405060708090distanza [m]diametro del raggio [cm]70 80 90 10010011012013014
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE24]XT[3WSNOITCELESECNATSIDROTCETEDEPYTNOITISOP3WS]m[ECNATSIDB001KR105-52207-05309-074021-09B002K
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE25GNIHSALF-TLOVNOITALERTLOVhsalF°NdeLeulBhsalF°NdeLdeR5,0<FFOFFO1-5,0FFO15,1-11FFO2-5,1115,2-
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE26RXJP6AlarmrelaisTurborelaisFehlerrelaisDS165112341234123JP1123JP5123123123JP2JP4JP3alarmrelayt
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE27RECEIVER INTERNAL ELEMENTSP1 - trimmer for the regulation of the signal level. Normally regula
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE281234SW3POWER12V1V2V3LEDTXDS1653JP6SW3 - selector for the regulation of the transmitter power
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE29fig.12TERMINAL BLOCK OFTHE RECEIVERC1N1C2N2C3N3SIGV+V-alimentazione 11-30 Vcccontatto relè d&a
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE3STANDARD STARTING CONDITION(Read ahead)• SW1 - position 1 (minimum threshold level)• SW2 - posi
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE30ACCESSORIES FOR RK100/200BLAL02 -Optical alignment lampThe RK series detectors on installation
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE311. OBJECTEDS S.r.l. - Via Cà Nova Zampieri 6, 37057 S. G. Lupatoto - Verona, Italy (hereinafte
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE32EDS - srlELECTRONIC DETECTION SYSTEMSVia Ca' Nova Zampieri 637057 S.G. Lupatoto - VERONA
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE4QUICK INSTALLATIONThe procedure below is intended for trained personell with previous experien
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE5GENERALNote : the following instructions are suitable for the RK100B and RK200B models.The RK10
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE63 - INSTALLATION3.1 - For the installation of the RK100/200B we suggest to use, besides the nor
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE74 - CABLE CONNECTIONS4.1 - the low detector’s power consumption (20 mA with normally open al
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE85 - ELECTRICAL CONNECTIONS AND INITIAL SETUP5.1 - Connect the device cables as shown on the lab
EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE95.2 - Jumper SettingsJP1- to enter/exit the optical alignment procedure.To activate the procedu