EDS RK 90 R Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Détecteurs de fumée EDS RK 90 R. EDS RK 90 R User guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - RK 90 R

1EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDEREFLECTIVE TYPEOPTICAL BEAM SMOKEDETECTORRK 90 RUSER GUIDETECHNICAL INSTRUCTIONS FORINSTALLA

Page 2 - CHAPTER INDEX

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE106 - OPERATION 6.1 - the RK90R detector is equipped with 2 circuits of detection of the smoke p

Page 3 - STANDARD STARTING CONDITION

11EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE7 - OPTICAL ALIGNMENT7.1 - proceed with the optical alignment of the detector and FX reflect

Page 4 - QUICK INSTALLATION

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE128 - SETUP OF THE OBSCURATION CIRCUITSetting operations of the electric signal must be perf

Page 5 - 2 - RELEVANT STANDARDS

13EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE• on the detector slowly turn the screw V1 clockwise and then look at the value of the signal

Page 6 - 3 - INSTALLATION

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE148.13 - After having executed the operations of fine optic alignment using the multimeter or t

Page 7 - 4 - CABLE CONNECTIONS

15EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE9 - SETTING OF TURBULENCE CIRCUIT9.1 - The RK90R detector is equipped with a special additio

Page 8

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE1610 - DETECTOR’S ACTIVATION10.1 - put the jumper of Initial Set JP1 in position 1-2 (OFF)10.2 -

Page 9

17EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE12 - OPERATIONAL TEST12.1 - verification of the circuit sensitive to the obscuration.The verif

Page 10 - 6 - OPERATION

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE1813 - FAULT OUTPUT13.1 - The contact of fault/malfunction relay is available on the terminal bl

Page 11 - 7 - OPTICAL ALIGNMENT

19EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE16 - MAINTENANCE16.1 - the instrument asks for a simple and periodic maintenance. It can be pr

Page 12

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE2CHAPTER INDEX1 - Qualified Personnel2 - Relevant Standards3 - Installation4 - Cable Connections

Page 13

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE2018 -TECHNICAL DATA• Model: RK90R• Type: Reflective type Optical Beam Smoke Detector• Manufact

Page 14

21EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDErivelatore riflettorefig.1svitare le due viti lateraliunscrew the two sides screwinsert thescr

Page 15

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE22riflettoreLAL 02lampadadisco biancowhite discdiodo fotoemittentephotoemitting diodeforoholefig

Page 16 - 11 - AUTOCOMPENSATION

23EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDEfig.50 10203040506001020304050distanza [m]diametro del raggio [cm]fig.6

Page 17 - 12 - OPERATIONAL TEST

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE24fig.77PJNOCAZNATSIDALLEDENOIZELES7PJNOCAZNATSIDALLEDENOIZELES7PJNOCAZNATSIDALLEDENOIZELES7PJNO

Page 18 - 15 - FRONTAL LEDS OPERATION

25EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDEGNIHSALF-TLOVNOITALERTLOVhsalF°NdeLeulBhsalF°NdeLdeR5,0<FFOFFO1-5,0FFO15,1-11FFO2-5,1115,2-

Page 19 - 17 - SENSITIVITY SELECTION

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE26123123123123123JP4JP3JP2V1V2V3JP7JP6RX TXJP1JP5123456789alarmrelayturborelayfaultrelaySW1SW212

Page 20 - 18 -TECHNICAL DATA

27EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDEINTERNAL PARTSP1 - Signal level regulation trimmer. P1 is factory preset to 50-60%, that corre

Page 21

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE28C1N1C2N2C3N3SIGV+V-alimentazione 11-30 Vcccontatto relè d'ALLARMEcontatto relè TURBOLENZA

Page 22

29EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDEExample of RK90R connection with a zones Control UnitC1C2C3SIGV+V-alimentazione 11-30 Vccconta

Page 23

3EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDESTANDARD STARTING CONDITION• SW1 - position 1 (minimum threshold level)• SW2 - position 1 (mini

Page 24

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE30ACCESSORIES FOR RK90RFX01- round reflectorDistance max.: 25mDiameter 85 mm.FX02 - Two round re

Page 25

31EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE1. OBJECTEDS S.r.l. - Via Cà Nova Zampieri 6, 37057 S. G. Lupatoto - Verona, Italy (hereinafte

Page 26 - Turborelais

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE32EDS - srlELECTRONIC DETECTION SYSTEMSVia Ca' Nova Zampieri 637057 S.G. Lupatoto - VERONA

Page 27 - INTERNAL PARTS

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE4QUICK INSTALLATIONThe procedure below is intended for trained personell with previous experien

Page 28

5EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDEGENERALThe RK90R detector is a newly-conceived microprocessor linear smoke detector, that ba

Page 29 - CENTRALE DI CONTROLLO

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE63 - INSTALLATION3.1 - For the installation of the RK90R detector, we advise to use besides the

Page 30 - ACCESSORIES FOR RK90R

7EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE4 - CABLE CONNECTIONS4.1 - The low detector’s power consumption (14 mA with normally open al

Page 31

EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE85 - ELECTRICAL CONNECTIONS AND INITIAL SETUP5.1 - Connect the device cables as shows on the lab

Page 32 - EDS - srl

9EDS - RK90R - OPTICAL BEAM SMOKE DETECTOR - USER GUIDE5.2 - JUMPER SETTINGSJP1- to enter/exit the optical alignment procedure. To activate the proced

Commentaires sur ces manuels

Pas de commentaire